Tests TS 101-952
TS-101-952-1 is a technical specification written by ETSI experts.
It provides a set of test methods to verify the electrical characteristics of an xDSL filter deployed in Europe.
This standard applies for Central Office, as well as CPE, filters. It allows to make sure that the filter will function correctly without impacting the loop characteristics. These tests are complementary to TR-127 tes t s def ined by the Broadband Forum which allows to dynamically validate the filter in its DSL system, by insuring that POTS transients will not impact the DSL link.
Ref | Tests | Pack Start | Pack Confort | Pack Zen |
6.2 | DC requi rements | |||
6.2.1 | DC resistance to earth | • | • | • |
6.2.2 | DC insulation resi stance between A-wire and B-wire | • | • | • |
6.2.3 | DC series resi stance RDC | • | • | |
6.3 | Ringing frequency requirements | |||
6.3.1 | Ringing voltage drop at 25 Hz and 50 Hz | • | ||
6.3.2 | ZInRing impedance in the presence of ringing at 25 Hz and 50 Hz | • | ||
6.3.3 | Total harmonic distortion at 25 Hz and 50 Hz | • | ||
6.4 | POTS pass band loss requirements (on-hook) | |||
6.4.1 | On-hook requirement for the case of high impedance termination | |||
6.4.2 | On-hook requirement for the case of low impedance termination | • | • | |
6.4.2.1 | Low impedance on-hook POTS pass band insertion loss | • | • | |
6.4.2.2 | Low impedance on-hook POTS pass band insertion loss distortion | • | • | |
6.5 | POTS pass band loss requirements (off-hook) | |||
6.5.1 | Off-hook POTS pass band insertion loss | • | • | • |
6.5.2 | Off-hook POTS pass band insertion loss di stortion | • | • | • |
6.6 | POTS pass band return loss requirement s (off-hook) | |||
6.6.1 | POTS pass band return loss requirement s, option A | • | • | • |
6.6.2 | POTS pass band return loss requirement s, option B | • | • | • |
6.7 | Requirements relating to metering pul ses at 12 kHz or 16 kHz (optional) | |||
6.8 | Unbalance about Earth | |||
6.8.1 | Unbalance of the low pass part | • | • | |
6.8.2 | Unbalance of the high pass part for alternative B or C | • | • | |
6.9 | xDSL band requirements | |||
6.9.1 | xDSL band on-hook i solation between LINE and POTS port | • | • | |
6.9.2 | xDSL band off-hook i solation between LINE and POTS port | • | • | • |
6.9.3 | Transition band signal loss: IL between POTS port and LINE port (optional) | |||
6.9.4 | xDSL signal Loss : IL LINE port to xDSL port | |||
6.9.4.1 | High pass alternatives A and B | |||
6.9.4.2 | High pass alternative C | |||
6.10 | Noise levels | |||
6.10.1 | POTS band audible noi se level | • | ||
6.10.2 | xDSL band noi se level | • | ||
6.11 | Distortion | |||
6.11.1 | POTS band intermodulation distortion | • | • | |
6.11.2 | Extended xDSL band intermodulation distortion (informative) | |||
6.12 | Group delay di stortion | • | ||
6.13 | POTS transient effects (informative) | Voir TR-127 | ||
6.14 | Requirements for Common Mode Rejection (optional) | • | ||
6.15 | Requirements for Crosstalk at the LE (optional) |